Medição com boost :: posix_time :: microsec_clock tem erro mais de dez microssegundos?

Eu tenho o seguinte código:

long long unsigned int GetCurrentTimestamp()
{
   LARGE_INTEGER res;
   QueryPerformanceCounter(&res);
   return res.QuadPart;
}


long long unsigned int initalizeFrequency()
{
   LARGE_INTEGER res;
   QueryPerformanceFrequency(&res);
   return res.QuadPart;
}


//start time stamp
boost::posix_time::ptime startTime = boost::posix_time::microsec_clock::local_time();
long long unsigned int start = GetCurrentTimestamp();


// ....
// execution that should be measured
// ....

long long unsigned int end = GetCurrentTimestamp();
boost::posix_time::ptime endTime = boost::posix_time::microsec_clock::local_time();
boost::posix_time::time_duration duration = endTime - startTime;
std::cout << "Duration by Boost posix: " << duration.total_microseconds() <<std::endl;
std::cout << "Processing time is " << ((end - start) * 1000000 / initalizeFrequency()) 
            << " microsec "<< std::endl;

O resultado deste código é

Duration by Boost posix: 0
Processing time is 24 microsec

Por que existe uma divergência tão grande? O Boost é uma droga tanto quanto deve medir microssegundos, mas mede microssegundos com um décimo de microssegundos de erro ???

questionAnswers(2)